14.4. Settings for terrains with middle degree of mineralization
<TDAVM> Terrain optimized setting in discrimination mode and automatic ground
balance for no contaminated terrains with middle degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: one level before the zoom level
GROUND switch: position „AUTO“
AUTO ZONES switch: position „2“ or „1
DISCR LEVEL potentiometer: at LTC48X v2 of level „4.5“, while at LTC48X v1 of level „9
DISCR WIDTH potentiometer: of level „NORM“
DISCR DEPTH potentiometer: of levels from „7“ to „10“
<TDGVM> Terrain optimized setting in discrimination mode and manual ground
balance for no contaminated terrains with middle degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: one level before the zoom level
GROUND switch: position „MANUAL“
GROUND potentiometer: level at which the metal detector is balanced to the terrain (usually
between levels from "3" to "7")
DISCR LEVEL potentiometer: at LTC48X v2 of level „4.5“, while at LTC48X v1 of level „9
DISCR WIDTH potentiometer: of level „NORM“
DISCR DEPTH potentiometer: of levels from „7“ to „10“
<TDACM> Terrain optimized setting in discrimination mode and automatic ground
balance for contaminated terrains with middle degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: one level before the zoom level
GROUND switch: position „AUTO“
AUTO ZONES switch: position „2“ or „1
DISCR LEVEL potentiometer: at LTC48X v2 of level „5.5“, while at LTC48X v1 of level „10“
DISCR WIDTH potentiometer: at LTC48X v2 of level „1“, while at LTC48X v1 of level „3“
DISCR DEPTH potentiometer: of levels from „8“ to „10“
<TDGCM> Terrain optimized setting in discrimination mode and manual ground
balance for contaminated terrains with middle degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: one level before the zoom level
GROUND switch: position „MANUAL“
GROUND potentiometer: level at which the metal detector is balanced to the terrain (usually
between levels from "3" to "7")
DISCR LEVEL potentiometer: at LTC48X v2 of level „5.5“, while at LTC48X v1 of level „10“
DISCR WIDTH potentiometer: at LTC48X v2 of level „1“, while at LTC48X v1 of level „3“
DISCR DEPTH potentiometer: of levels from „8“ to „10“